Price
Request a Quote
Stock
Call for Pricing & Availablility

  • Supply Voltage - 12-28 Vdc (Loop Powered) 0.025 A Maximum at 24 Vdc
  • Output - 4-20 mA/20-4 mA
  • Range - 0.8 to 30 feet (0.24 to 9.1 meters)
  • Enclosure Type - PVC, 1/2" NPT x 2 Conduits
  • Process Connection - 1-1/2" Hygienic Clamp (Maximum 16 feet Range)
  • Communication - No Communication
  • Options - Without Option

Specifications

Accuracy

  • ± 0.1 % of, Max.
  • ± 0.25 % of, Max.
  • Loop Powered Display: Reading ± 0.5 %

Ambient Temperature Range

  • -40° to 60° C (-40° to 140° F)

Calibration

  • Push Button

Communication

  • HART

Conduit Connection

  • 2 x 1/2” NPT Female

Consumption

  • Power: 0.025 A, Max.

Current

  • Loop Powered Display: 150 mA - Max.

Display

  • Head Mounted LCD Display
  • Loop Powered Display: 4-1/2-Digit LCD 1/2” High

Enclosure, Body Material

  • PVC-94V0

Environmental Protection

  • IP67
  • NEMA 6

Humidity

  • Loop Powered Display: 0 to 95 % Non-Condensing

Output

  • 20-4 mA
  • 4-20 mA

Pressure Range

  • bar: 1 to 5
  • kPa: 100 to 500
  • psi: 14.5 to 72.52

Range

  • 0.4 to 30 feet (0.12 to 9.1 metres)
  • Loop Powered Display: 3.5-22 mA [22 mA & above = LOE (Loss of Echo)]

Resolution

  • Output: 0.006 mA

Sensor, Probe Material

  • Sensor: 316L Stainless Steel

Supply Voltage

  • 12-28 Vdc, 0.025 A Max.

Temperature Range

  • Sanitary Nozzle: -40° to 130° C (-40° to 266° F) for 1/2-Hour Steam Cleaning
  • Sanitary Nozzle: -40° to 60° C (-40° to 140° F) for No Steam Cleaning (CIP)

Tri-Clamp Connection

  • 1-1/2” Hygienic Tri-Clamp
  • 2” Hygienic Tri-Clamp

Voltage Drop

  • Loop Powered Display: 0.95 V at 20 mA

show more