PD6606-L3N

Price
Request a Quote
Stock
Call for Pricing & Availablility

  • Product Type: 1/8 DIN Loop-Powered Digital Panel Meter
  • Inputs: Current (4-20 mA)
  • Outputs: (2) Open Collectors, (1) 4-20 mA Output
  • Display: Dual Line, 0.7" & 0.4" High, 5 & 8 Digits, Decimal, LCD
  • Backlight: Standard / Red on Alarm
  • Approvals: ATEX (IS), CE, UL/C-UL, IEC (IS), UL/C-UL (IS, NI)
  • Warranty: 3 years

Specifications

Display

  • Dual-line LCD with backlight
  • Both lines 14-segment alphanumeric
  • Top: 0.7” / 17.8 mm
  • Bottom: 0.4” / 10.2 mm
  • Display may be programmed to turn red and flash a user-defined message on alarm condition
  • PD6603 & PD6607 only: Top line: 7-segment numeric, FT-IN
  • Bottom line: 14-segment alphanumeric

Operating Temperature Range

  • -40° to 75° C for Safe Area Products
  • -40° to 70° C for Hazardous Area Products

Storage Temperature Range

  • -40° to 85° C

Relative Humidity

  • 0 to 90 % Non-condensing
  • Printed circuit boards are conformally coated

Connections

  • Removable screw terminals accept 12 to 22 AWG wire

Overall Dimensions

  • 4.68”x 2.45”x 3.79”
  • 119 mm x 62 mm x 96 mm
  • W x H x D

Weight

  • 8.7 oz. / 247 g with option board

Warranty

  • 3 Years Parts and Labor

Input

  • 4-20 mA

Hazardous Area Approvals

  • ATEX: II 1G, Ex ia IIC T4 Ga, Ta = -40° C to +70° C Certificate Number: CML 17ATEX2015X
  • IECEx: Ex ia IIC T4 Ga, Tamb = -40° C to +70° C Certificate Number: IECEx CML 17.0008X
  • UL & C-UL Listed as Intrinsically Safe and Nonincendive: Class I, Div. 1, Groups A, B, C and D T4, Class I, Div. 2, Groups A, B, C and D T4 Ex ia IIC T4 (Canada), Class I Zone 0, Zone 1 AEx ia IIC T4 (U.S.) Class I Zone 2, Group IIC T4 (U.S.) PROCESS CONTROL EQUIPMENT FOR USE IN HAZARDOUS LOCATIONS
  • UL & C-UL 61010 Listed for Electrical Safety and Type 4X Environmental: Standards for Safety: IEC 61010-1:2010 (3rd Edition), UL 61010-1, 3rd Edition, CAN/CSA C22.2 No. 61010-1-12, 3rd Edition, Additional Standards: UL 50E
show more