PD2-6000-6H7

Price
Request a Quote
Stock
Call for Pricing & Availablility

  • Product Type: Large Display NEMA 4X Process Meter
  • Inputs: Current (4-20 mA), Voltage (0-10 V)
  • Outputs: 4 Relays & 4-20 mA Output
  • Power: 85-265 VAC, 90-265 VDC
  • Transmitter Power: 24 VDC @ 200 mA + 24 VDC @ 40 mA
  • Display: SunBright, 1.8", Dual Line, 6 Digits, Red LED
  • Serial Communications: RS-485 Modbus
  • Approvals: UL/C-UL
  • Warranty: 3 years

Specifications

Display

  • Two lines with 1.8” (46 mm) High Digits, Red LEDs, 6 Digits per line (-99999 to 999999), with Lead Zero Blanking

Display Intensity

  • Eight user selectable intensity levels

Display Update Rate

  • 5/second (200 ms)

Overrange

  • Display flashes 999999

Underrange

  • Display flashes -99999

Display Assignment

  • Line 1 and line 2 may be assigned to PV1, PV2, PCT, d r-u, d gross, d nt-g, max/min, max & min, Set Points, units (Line 2 only), or Modbus Input.

Programming Methods

  • Four Programming Buttons, digital inputs, PC and MeterView Pro Software, Modbus registers, or cloning using Copy function

F4 Digital Input Contacts

  • 3.3 Vdc on Contact. Connect Normally Open Contacts across F4 to COM

F4 Digital Input Logic Levels

  • Logic Low: 0 to 1.25 Vdc
  • Logic High: 3 to 5 Vdc

Noise Filter

  • Programmable from 2 to 199 (0 will disable filter)

Filter Bypass

  • Programmable from 0.1 to 99.9 % of Calibrated Span Recalibration: All Ranges are calibrated at the factory. Recalibration is recommended at Least every 12 months

Maximum / Minimum Display

  • Max./Min. Readings reached by the process are stored until reset by the user or until power to the meter is turned off. Tare: Tare function zeros out the meter to accommodate for weight of a Container. Tare function can be assigned to a function key, F4 terminal, or a Digital Input.

Password

  • Three Programmable passwords restrict modification of programmed settings.

Non-Volatile Memory

  • All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost.

Power Options

  • 85-265 Vac 50/60 Hz, 90-265 Vdc, 20 W max or 12-24 Vdc ± 10 %, 15 W Max. Powered over USB for configuration only.

Fuse

  • Required External Fuse: UL Recognized, 5 A max., Slow Blow, up to 6 metres may share one 5 A fuse

Normal Mode Rejection

  • Greater than 60 dB at 50/60 Hz

Isolation

  • 4 kV Input/Output-to-Power Line, 500 V Input-to-Output or Output-to-P+ Supply

Overvoltage Category

  • Installation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.

Environmental

  • Relative Humidity: 0 to 90 % Non-Condensing
  • Storage Temperature Range: -40 to 85° C
  • Operating Temperature Range: -40 to 65° C

Connections

  • Removable and integrated screw terminal blocks accept 12 to 22 AWG wire

Enclosure

  • UL Type 4X, IP65 rated. Polycarbonate & glass blended plastic Case, color: gray. Includes four PG11 through-hole conduit openings, with two factory installed PG11, IP68, Black nylon threaded hole plugs with backing nuts.

Wall Mounting

  • Four (4) mounting holes provided for mounting meter to wall

Pipe Mounting

  • Optional Pipe Mounting Kit (PDA6260) Allows for Pipe Mounting

Tightening Torque

  • RS-485 Terminals: 2.2 lb-in (0.25 Nm)
  • Removable Screw Terminals: 5 lb-in (0.56 Nm), Digital I/O

Overall Dimensions

  • 10.63” x 12.59” x 4.77” (270 mm x 319.7 mm x 121.2 mm) (W x H x D)

Weight

  • 6.10 lbs (2.76 kg)

UL File Number

  • UL & C-UL Listed. E160849, 508 Industrial Control Equipment.
  • Note: Instruments with Light / Horn option installed are not Marked as UL & C-UL

Warranty

  • 3 Years Parts & Labor