PD8-6000 ProtEX-MAX Explosion-Proof Process Meter

Brand: Precision Digital Corporation

The ProtEX-MAX™ PD8-6000 explosion-proof process meter offers all the functionality of the ProVu PD6000 as a fully FM, CSA, ATEX, and IECEx approved explosion-proof product. 

It accepts a process current (4-20 mA) or process voltage (0-5V, 1-5V, etc.) signal and displays it on a dual-line, 6-digit Sunbright® sunlight readable display. 

The meter includes a 24 VDC power supply to drive the transmitter and can be equipped with four internal relays and a 4-20 mA output. 

The PD8-6000 can be programmed and operated without opening the housing by using the built-in SafeTouch® through-glass buttons or the RS485 serial communication port with free Modbus® protocol.
Features
  • Fully-Approved Explosion-Proof Meter
  • 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, and ±10 V Field Selectable Inputs with ±0.03% Accuracy
  • Dual-Line 6-Digit Display, 0.6" / 15 mm and 0.46" / 12 mm
  • SafeTouch Through-Glass Button Programming
  • Display Mountable at 0°, 90°, 180°, & 270°
  • Isolated 24 VDC at 25 mA Transmitter Power Supply
  • Easy Field Scaling in Engineering Units without Applying an Input
  • 4 Relays with Interlocking Capability + Isolated 4-20 mA Output Option
  • Free PC-Based, On-Board, MeterView Pro USB Programming Software
  • SunBright Display Standard Feature; Great for Outdoor Applications
  • Operating Temperature Range: -40 to 60°C / -40 to 140°F
  • FM Approved as Explosion-Proof / Dust-Ignition-Proof / Flame-Proof
  • CSA Certified as Explosion-Proof / Dust-Ignition-Proof / Flame-Proof
  • ATEX and IECEx Certified as Flame-Proof
  • Input Power Options: 85-265 VAC / 90-265 VDC or 12-24 VDC / 12-24 VAC
  • Display Input in Two Different Scales Simultaneously - Great for Level Applications
  • Multi-Pump Alternation Control
  • Round Horizontal Tank Function; Just Enter Diameter & Length
  • 32-Point Linearization, Square Root Extraction and Programmable Exponent Function
  • Password Protection
  • Programmable Display, Function Keys & Digital Inputs
  • Flanges for Wall or Pipe Mounting
  • Explosion-Proof, IP68, NEMA 4X Die-Cast Aluminum Enclosure
  • On-Board RS-485 Serial Communications
  • Modbus® RTU Communication Protocol Standard
  • Four 3/4" NPT Threaded Conduit Openings - Two Plugs Installed
  • Pipe Mounting Kits
  • Stainless Steel Tag Available
  • 3-Year Warranty

Models matching criteria: 12
PD8-6000-6H7 view more
  • Product Type: Explosion-Proof Process Meter
  • Inputs: Current (4-20 mA), Voltage (0-10 V)
  • Outputs: 4 Relays & 4-20 mA Output
  • Power: 85-265 VAC, 90-265 VDC
  • Transmitter Power: 24 VDC @ 25 mA + 24 VDC @ 25 mA
  • Display: SunBright, 0.6", Dual Line, 6 Digits, Red LED
  • Approvals: ATEX (FP), CE, CSA (XP), FM (XP), IEC (FP)
Call for Pricing & Availablility
Does not ship to OH, United States
PD8-6000-7H7 view more
  • Product Type: Explosion-Proof Process Meter
  • Inputs: Current (4-20 mA), Voltage (0-10 V)
  • Outputs: 4 Relays & 4-20 mA Output
  • Power: 12-24 VDC/VAC
  • Transmitter Power: 24 VDC @ 25 mA + 24 VDC @ 25 mA
  • Display: SunBright, 0.6", Dual Line, 6 Digits, Red LED
  • Approvals: ATEX (FP), CE, CSA (XP), FM (XP), IEC (FP)
Call for Pricing & Availablility
Does not ship to OH, United States
PD8-6000-6H0 view more
  • Product Type: Explosion-Proof Process Meter
  • Inputs: Current (4-20 mA), Voltage (0-10 V)
  • Outputs: None
  • Power: 85-265 VAC, 90-265 VDC
  • Transmitter Power: 24 VDC @ 25 mA
  • Display: SunBright, 0.6", Dual Line, 6 Digits, Red LED
  • Approvals: ATEX (FP), CE, CSA (XP), FM (XP), IEC (FP)
Call for Pricing & Availablility
Does not ship to OH, United States
  • Power - 12/24 Vdc
  • Relay - 2 Relays
Call for Pricing & Availablility
Does not ship to OH, United States
  • Power - 12/24 Vdc
  • Relay - 4-20 mA Output
Call for Pricing & Availablility
Does not ship to OH, United States
  • Power - 12/24 Vdc
  • Relay - 2 Relays & 4-20 mA Output
Call for Pricing & Availablility
Does not ship to OH, United States
  • Power - 85-265 Vac
  • Relay - 4 Relays
Call for Pricing & Availablility
Does not ship to OH, United States
  • Power - 85-265 Vac
  • Relay - 2 Relays
Call for Pricing & Availablility
Does not ship to OH, United States
  • Power - 12/24 Vdc
  • Relay - 4 Relays
Call for Pricing & Availablility
Does not ship to OH, United States
  • Power - 85-265 Vac
  • Relay - 2 Relays & 4-20 mA Output
Call for Pricing & Availablility
Does not ship to OH, United States
  • Power - 85-265 Vac
  • Relay - 4-20 mA Output
Call for Pricing & Availablility
Does not ship to OH, United States
PD8-6000-7H0 view more
  • Product Type: Explosion-Proof Process Meter
  • Inputs: Current (4-20 mA), Voltage (0-10 V)
  • Outputs: None
  • Power: 12-24 VDC/VAC
  • Transmitter Power: 24 VDC @ 25 mA
  • Display: SunBright, 0.6", Dual Line, 6 Digits, Red LED
  • Approvals: ATEX (FP), CE, CSA (XP), FM (XP), IEC (FP)
Call for Pricing & Availablility
Does not ship to OH, United States

Specifications

Accuracy

  • ± 0.03 %

Approvals & Certifications

  • ATEX, II 2 GD Ex d IIC T* Gb Ex Tb IIIC T90° C Db
  • CSA Class I, Div. 1, Groups B, C, D, Class II, Div. 1, Groups E, F, G Class III, Div. 1, Class I, Zone 1 Ex d IIC Zone 21 Ex Tb IIIC T90° C
  • FM Class I, Div. 1, Groups B, C, D Class II, Div. 1, Groups E, F, G Class III, Div. 1, T5/T6 Class I, Zone 1, AEx d, IIC Gb T5/T6 Zone 21, AEx Tb IIIC T90° C
  • IEC Ex d IIC T* Gb Ex Tb IIIC T90° C Db

Communication

  • Modbus

Display

  • 6-Digit Display

Enclosure, Body Material

  • Aluminum

Environmental Protection

  • IP66
  • IP68
  • NEMA 4X
  • NEMA 7
  • NEMA 9

Input

  • ± 10 VCD
  • 0-20 mA
  • 4-20 mA

Operating Temperature

  • -40° to 65° C (-40° to 150° F)

Operating Voltages

  • 50/60 Hz

Power Supply

  • 12-36 Vdc
  • 85-265 Vac

Relay Output

  • 2 or 4 SPDT
  • 4 SPST

Update Time

  • 5 seconds
show more