MIST M46 RTD Temperature Transmitter

Part Number: MIST M46 Brand: Intempco Controls, Inc
Price
Request a Quote
Stock
Call for Pricing & Availablility

MIST M46 assemblies are designed for very corrosive environments such as plating shops and chemical processing plants. 

Vapors from acids and various corrosive chemicals do not damage these sensors. 

These assemblies are also the ideal solution for laboratory test applications where a high accuracy and dependable temperature measurement in corrosive liquids is required. 

Designed for both 40° C (104° F) or (53.89° C) 129° F acid bath temperature sensor applications. M46 meets the anodize temperature spec of ±2° F or better.
Features
  • Factory calibrated 4-20 mA output to a customer specified temperature range
  • Operating temperature range of -50° to 200º C (-58° to 392º F)
  • Can be re-programed, re-calibrated in-house
  • 1/2" or 3/4" NPT Teflon fitting
  • Corrosion resistant
  • Teflon jacketed 5/16" diameter probe with Teflon housing
  • Cable supplied is a Teflon jacketed 22 AWG stranded 4-conductor, copper silver plated
  • Probe lengths standard or custom

Specifications

Accuracy

  • ± (0.10° C (0.18° F) + 0.10 % of Calibrated Span) with Two-Point Calibration
  • ± (0.25° C (0.45° F) + 0.40 % of Span) with One-Point Calibration

Cable Material

  • PVC
  • Teflon

Cable Type

  • 22 AWG Stranded 4-Conductor

Electrical - Free Leads

  • 12” Long & Less are Single Stranded Leads, 22 AWG

Environmental Protection

  • IP67 Hermetically Sealed
  • NEMA 6P Hermetically Sealed

Input Impedance

  • 1,000 ohms Min. (of Measuring Device, for Voltage Output)

Isolation

  • 500 Vdc Input/Output

Materials of Construction

  • Armor & Overbraid: Stainless Steel
  • Shrink for Teflon Cable: Polyolefin

NPT Connection

  • 1/2” NPT Male
  • 3/4” NPT Male

Operating Pressure

  • Sensor psig: 500 (kPa: 3,447, bar: 34.47)

Operating Temperature

  • Housing: -40° to 80° C (-40° to 175° F)

Output

  • 0-10 Vdc Linear to Temperature
  • 0-5 Vdc Linear to Temperature
  • 1-5 Vdc Linear to Temperature
  • 4-20 mA Loop Powered, Linear to Temperature

Power Supply

  • 12-32 Vdc Polarity Protected

Power Supply Effect

  • 0.001 %/V

Process Connection Material

  • Teflon

RFI/EMI Effect

  • RFI: 1 % or Less Typical

RTD Type

  • Pt100

Sensor Circuit

  • 2.5 mA Downscale for 4-20 mA Output
  • 24 mA Upscale for 4-20 mA Output

Sensor, Probe Connection

  • 2-Wire
  • 3-Wire

Sensor, Probe Diameter

  • 3/8” (9.5 mm)
  • 5/16” (0.79 cm)

Sensor, Probe Material

  • PFA Teflon Clad 316 Stainless Steel Tube
  • PTFE Teflon Clad 316 Stainless Steel Tube

Sensor, Probe Type

  • RTD

Stability

  • Long Term Drift: ≤ 0.1 % of Full Scale Per Year

Storage Temperature

  • -40° to 80° C (-40° to 176° F)

Temperature Effect

  • ± 0.001 % of Span/°C

Temperature Range

  • -50° to 200° C (-58° to 392° F)

Update Time

  • Warmup: 30 seconds

Wetted Materials

  • 316 Stainless Steel, Dual Certified
  • 316L Stainless Steel, Dual Certified

  • Industrial Design, Hermetically Sealed, With Extension Cable
  • All Teflon Construction
  • Connection: 1/2" and 3/4" Teflon
  • Acid Bath Temperature Sensor
  • Meets Anodize Temperature Spec
show more