TT301 Temperature Transmitter

Brand: Smar International Corp

Specifications
  • Output: HART Protocol, 2-Wire 4-20mA
  • Input Range: -200°C to +1750°C, -328°F to +3182°F
    • Minimum Span: +10°C to +60°C, +50°F to +140°F
  • Control: PID Capability
  • Power Supply
    • Bus Powered: 12 to 45 Vdc.
  • Digital Accuracy: ±0.2 to ±0.6°C
  • Display: 4-1/2 digit numerical and 5-Character alphanumerical LCD indicator
  • Burnout: Upscale
  • Mounting Bracket: Carbon Steel or 316 Stainless Steel
  • Electrical Connection
    • 1/2"-14 NPT
    • PG 13.5 DIN
    • M20 X 1.5
  • Damping Adjustment: User Configurable from 0 to 32 seconds
  • Power Supply Effect: ± 0.005% of calibrated span per volt
  • CSA Intrinsically Safe, Explosion Proof, Dust Ignition Proof, Non-Incendive
  • Order includes a SMAR Magnetic Screwdriver for adjustments if the LCD Display option is selected in the configuration below

Specifications

Accuracy

  • ± 0.02 % of Span

Alarm

  • HART: in Case of Sensor or Circuit Failure, the Self Diagnostics Drives the Output to 3.6 to 21.0 mA, According to the User's Choice & NAMUR NE43 Specification.

Ambient Temperature Range

  • -40° to 85° C (-40° to 185° F)

Approvals & Certifications

  • CEPEL
  • CSA
  • EXAM
  • FM
  • NEMKO ATEX

Burn-Out

  • Upscale

Communication

  • HART: 2-Wire, 4-20 mA According to NAMUR NE43 Specification, with Super-imposed Digital Communication.

Configuration

  • Software CONF401, DDCON100, or HpC301 & HpC401. Can Also be Configured Using DD & FDT/DTM Tools, & Can be Partially Configured through Local Adjustment

Control Functions Characteristics

  • HART: PID Control, Alarm & Set Point Ramp Generator

Damping Adjustment

  • User Configurable from 0 to 32 seconds (via Digital Communication).

Digital Stability

  • ± 0.1 % of Reading or +0.1° C (0.18° F), whichever is greater, for 1-Year for Thermocouple
  • ± 0.1 % of Reading or +0.1° C (0.18° F), whichever is greater, for 2-Years for RTDs

Display

  • 4-1/2-Digit LCD Indicator

Electrical Connectors

  • 1/2” NPT

Electromagnetic Interference Effect

  • Approved According to IEC 61326-1: 2006, IEC 61326-2-3: 2006, IEC 61000-6-4: 2006, IEC 61000-6-2: 2005

Enclosure Finish

  • Gray Munsell 6.5 Polyester Paint

Enclosure, Body Material

  • 316 Stainless Steel IP/TYPE, 316 Stainless Steel for Saline Atmosphere IPW/TYPEX
  • Copper-Free Aluminum IPW / TYPEX, Aluminum for Saline Atmosphere IPW / TYPEX, Aluminum IP / TYPE

Humidity

  • 0 to 100 % Relative Humidity

Input Power

  • HART: 12-45 Vdc

Mounting

  • 316 Stainless Steel Bracket & Accessories
  • Can be Attached Directly to the Sensor. with an Optional Bracket can be Installed on a 2” Pipe or Fixed on a Wall or Panel.
  • Carbon Steel Bracket & Accessories

Operating Temperature - Display

  • -20° to 80° C (-4° to 176° F)
  • -40° to 85° C (-40° to 185° F), without Damage

Output

  • 2-Wire 4-20 mA

Power Supply Effect

  • ± 0.005 % of Calibrated Span Per Volt

Sensor, Probe Connection

  • 2-Wire
  • 3-Wire
  • 4-Wire
  • Backup
  • Differential

Sensor, Probe Type

  • J Thermocouple
  • K Thermocouple
  • RTD Pt100 - IEC
  • R Thermocouple
  • S Thermocouple

Span & Zero Adjustments

  • Non-Interactive, Via Local Adjustment & Digital Communication

Storage Temperature

  • -40° to 100° C (-40° to 212° F)

Temperature Effect

  • mV (-10 to 100 mV) TC (NBS: E, J, K, N): ± 0.03 % of the Input mV or 0.01 mV whichever is greater (10° C Variation)
  • mV (-6-22 mV), TC (NBS: B, R, S, T): ± 0.03 % of the Input mV or 0.002 mV whichever is greater -10° C Variation
  • Ohms: 0 to 400 ohms, RTD (IEC: Pt100): ± 0.03 % of the Input Resistance or 0.04 ohms, whichever is greater
show more