Case and Blow-Out Back
- Phenolic, Fiberglass Reinforced in 4-1/2” (125 mm) diameter
Fill
- Dry or Glycerin Filled. Silicone Fill Optional.
Socket
- AISI 316 Stainless Steel, TIG welded to the elastic element using 316 Stainless Steel
Connection
- 1/2” NPT threads, SS Restrictor Optional. Ranges ranges Stainless Steel 30,000# and above require Autoclave fitting
Bourdon Tube
- AISI 316 Stainless Steel. C-tube configuration for ranges below 1000 psi. Spiral tube configuration for higher ranges
Pointer
- Black Aluminum, micrometer adjustable
Dial
- White Aluminum with black markings in accordance with ASME B40.1 -2005
Accuracy
- ± 1.0 %: Wet, ± 0.5 %: Dry
- ± 1.6 % for 50,000# and 60,000# Ranges
Range Availability
- psi, Metric, and Dual Scales.
Process Temperature Limits
- -25° to +80° C / -13° TO 176° F
Ambient Temperature
- Dry: -40° to 185° F (-40° to 85° C)
- Glycerin Filled: 60° to 150° F (15° to 65° C)
- Silicone Filled: -50° to 150° F (-45° to 65° C)
Silicone Filled: -50° to 150° F (-45° to 65° C)
- Silicone Filled: -50° to 150° F (-45° to 65° C)
Overpressure Limits
- 30 % for ranges up to 870 psi (60 bar, as a percent of full scale value)
- 25 % for ranges from 870 to 1400 psi (100 bar, as a percent of full scale value)
- 15 % for ranges above 1400 psi (100 bar, as a percent of full scale value). (Over pressures up to 130 % of these values will not damage the movement).