Accuracy
- For Ranges 2, 3, or 4 & Level Model 316 Stainless Steel Diaphragm with Silicon or HaloCarbon Filling Fluid with Max.
Alarm
- HART: in Case of Sensor or Circuit Failure, the Self Diagnostics Drives the Output to 3.6 to 21.0 mA, According to the User's Choice & NAMUR NE43 Specification.
Ambient Temperature Range
- -40° to 85° C (-40° to 185° F)
Approvals & Certifications
- 3A Sanitary
- CEPEL
- CRN
- CSA
- EXAM
- EXIDA
- FM
- GOST
- LLOYD
- NEMKO ATEX
- NEPSI
Communication
- HART: 2-Wire, 4-20 mA According to NAMUR NE43 Specification, with Superimposed Digital Communication.
Configuration
- Software CONF401, DDCON100, or HpC301 & HpC401. Can Also be Configured Using DD & FDT/DTM Tools, & Can be Partially Configured through Local Adjustment
Control Functions Characteristics
- HART: PID Control (PID) & Totalizer (TOT)
Damping Adjustment
- User Configurable from 0 to 128 seconds (via Digital Communication)
Diaphragm Material
- 316 Stainless Steel
- Extension - 304L Stainless Steel
- Hastelloy C-276
Display
- 4-1/2-Digit Numerical & 5-Character Alphanumerical LCD Indicator
- None
Drain, Vent Valves & Plug
- 316 Stainless Steel
- Hastelloy C-276
- Monel 400
Electromagnetic Interference Effect
- Approved According to IEC 61326-1: 2006, IEC 61326-2-3: 2006, IEC 61000-6-4: 2006, IEC 61000-6-2: 2005
Enclosure Finish
- Polyester (Gray Munsell N 6.5) Paint
Environmental Protection
- IP66
- IP68
- NEMA 4X, 6P / IP66, 68
- NEMA 6P
Fill Material
- Fomblin Oil
- HaloCarbon 4.2 Oil
- Inert HaloCarbon
- Krytox Oil
- Silicone Oil
Flange Material
- 316 Stainless Steel
- Bolts & Nuts: Carbon Steel, 316 Stainless Steel
- Hastelloy C-276
- Monel 400
- Plated Carbon Steel
Humidity
- 0 to 100 % Relative Humidity
Input Power
- HART: 12-45 Vdc. Transient Suppressor Vmax = 65 Vp, Differential Mode - Bi-Directional, Low Current Leak & Capacitance, Meets the Standards: IEEE 61000-4-4 & IEEE 61000-4-5, less than 5 Nanosecond Response Time.
Mounting Position Effect
- Zero Shift of up to 250 Pa (1”H₂O) which can be Calibrated Out. No Span Effect
NPT Connection
- 1/2” NPT Female
- 1/4” NPT Female
Operating Temperature - Display
- -20° to 85° C (-4° to 185° F)
Overpressure & Static Pressure Limits
- 150#: psi a: 6 to psi: 235 (bar: -0.6 to 16, kPa: 60 to 1,620) at 93° C (199° F)
Power Supply Effect
- ± 0.005 % of Calibrated Span Per Volt
Pressure Range
- inH 2O: -200 to 200
- kPa: -2,500 to 2,500
- psi: -360 to 360
Process Temperature
- -40° to 100° C (-40° to 212° F)
Span & Zero Adjustments
- Non-Interactive, Via Digital Communication or Local Adjustment
Static Pressure Effect
- Span Error: for Range 1 & Level Transmitters: Correctable to ± 0.2 % of Reading Per 3.5 MPa (500) psi
- Zero Error: for Level Transmitter: ± 0.1 % of URL Per psi: 500 (bar: 34.47, kPa: 3,447) the Zero Error is Systematic Error That Can Be Eliminated by Calibrating at the Operating Static Pressure.
Storage Temperature
- -40° to 100° C (-40° to 212° F)
Temperature Effect
- ± [0.02 % of URL + 0.06 % of Span] Per 20° C (36° F)
- 6 mmH₂O Per 20° C (36° F) for 4” & DN 100