LSC52 Miniature Capacitance Level Switch

Part Number: LSC52 Brand: Intempco Controls, Inc
Price
Request a Quote
Stock
Call for Pricing & Availablility

The LSC52 is truly a high quality sensor, which can be used in harsh environments, for liquid level limit detection in metallic and non-metallic tanks containing electrically conductive or non-conductive liquids. 

The probe, fitting and housing are constructed of stainless 316, the isolator is Teflon. 

The LSC52 sensors feature built-in protection against reverse polarity, overvoltage and electrical shielding to deliver long-term reliability. 

The output is relay SPDT which can be configured as either NO or NC or both NO and NC.
Features
  • All stainless steel 316 construction, Teflon® isolator
  • Probe bare stainless steel or PFA Teflon clad
  • Integral electronic switching, relay output
  • Set-point calibration via one wire
  • Built-in slosh dampening
  • Hermetically sealed, vibration resistant construction
  • Operates on RF capacitance principle
  • For conductive and non-conductive liquids
  • Minimum or maximum limit detection

Specifications

Ambient Temperature Range

  • -40° to 85° C (-40° to 185° F)

Cable Length

  • Extension: 6.5 to 16.4 feet (2 to 5 metres)
  • Extension: Max.

Calibration

  • Set Point Via One Wire

Capacitance

  • 5 to 1,000 PF

Circuit Protection

  • Reverse Voltage

Consumption

  • Power: 120 mW, Max.
  • Power: 50 mA at 24 Vdc

Damping Adjustment

  • 1 second

Electrical Connectors

  • Electrical Termination: Lead Wires 22 AWG
  • M12 Micro-Connector (5 & 8-Pin Male)

Electrical Contacts

  • Normally Closed
  • Normally Open

Environmental Protection

  • IP66
  • IP67
  • NEMA 4X

Load

  • Load Capability: 0.3 A at 110 Vac, Max.
  • Load Capability: 1 A at 30 Vdc, Max.

Materials of Construction

  • Extension: PVC Insulation, 90° C (195° F) - Max.
  • Extension: Teflon, 200° C (392° F) - Max.
  • Fitting: 316 Stainless Steel

NPT Connection

  • 1/2” NPT Male
  • 1/4” NPT Male
  • 1/8” NPT Male
  • 3/8” NPT Male

Output

  • Probe: 1 mA - Max.
  • Probe: 1 Vac, Max.

Pressure Range

  • psi: 0 to 100 (kPa: 0 to 690, bar: 0 to 6.9)

Process Temperature

  • 100° C (212° F) - Max.

Sensitivity

  • 0.5 PF

Sensor, Probe Length

  • Probe: 1 to 36” (25.4 to 914.4 mm)

Sensor, Probe Material

  • Probe: Bare 316 Stainless Steel
  • Probe: PFA Teflon Jacketed

Supply Voltage

  • 12-30 Vdc

Switch Type

  • SPDT

Wetted Materials

  • 316 Stainless Steel
  • PFA Teflon

  • Limit Detection for all Type of Liquids
  • Use Teflon® Clad Probe for Conductive Liquids
  • Use Bare SS Probe for Clean Non-Clogging Oils and Fuels
  • For Side Mount and Bottom Mount Tank Applications
  • Leak Detection
  • Coolant Level Monitoring

show more