Price
Request a Quote
Stock
Call for Pricing & Availablility

  • Display - Standard
  • Power Supply - 12/24 Vdc
  • Relay - 4 Relays

Specifications

Alarm

  • Unused Alarm LEDs & Relays May be Disabled
  • User May Program Any Alarm for High or Low Trip Point

Approvals & Certifications

  • UL

Calibration

  • +10 Volts: Min. Span Input 1 & 2: 0.10 Volts
  • 4-20 mA: Min. Span Input 1 & Input 2: 0.15 mA

Communication

  • Serial Communication Adapters

Deadband

  • 0 to 100 % of Span
  • User Programmable

Display

  • Red LEDs
  • Upper: 0.60” High, Lower: 0.46” High

Electrical Connectors

  • Digital I/O
  • Removable Terminal Blocks Accept 12 to 20 AWG
  • RJ45 for External Relays

Environmental Protection

  • IP65
  • IP66
  • NEMA 4X / IP66

Humidity

  • 0 to 90 % Non-Condensing

Input

  • Two Channel

Isolation

  • 4 kV Input/Output-to-Power-Line
  • 500 V Input to Output or Output to P+ Supply

Mounting

  • 1/8” DIN Panel Cut-out Required. Two Panel Mounting Brackets Included.

Operating Temperature

  • -40° to 65° C (-40° to 150° F)

Output

  • 4-20 mA

Programming

  • Cloning Using Copy Function
  • Digital Inputs
  • Four Front Panel Buttons
  • Modbus Registers
  • PC & MeterView Pro Software

Rating

  • 2 or 4 SPDT Internal and/or 4 SPST External Relays

Relay Operation

  • Automatic (Non-Latching)
  • Latching (Requires Manual Acknowledge)
  • Off (Disable Unused Relays & Enable Interlock Feature, Manual ON/OFF Control Mode)
  • Pump Alternation Control (2 to 8 Relays)
  • Sampling (Based on Time)

Supply Voltage

  • 90-265 Vdc

Torque

  • 5 In/Lbs
show more