Price
Request a Quote
Stock
Call for Pricing & Availablility

  • Style - Inline
  • Size (O.D) - 2"

Specifications

Accuracy

  • Accuracy (Including Linearity): ± [1 % of Reading + (0.5 % of Full Scale + 0.05 %/°C)]

Approvals & Certifications

  • CE

Communication

  • RS-232C
  • RS-485 Modbus RTU

Compensated Temperature

  • -18° to 121° C (0° to 250° F)
  • -18° to 66° C (0° to 150° F)

Display

  • 2-Lines, 16-Characters Per Line, Backlit LCD

Environmental Protection

  • IP66
  • NEMA 4X

Frequency

  • Linear Signal Output: 0 to 1 kHz (Proportional to Flow for Total/Counter)

Input

  • Input Power Requirement: 115 Vac at 50/60 Hz, 100 mA
  • Input Power Requirement: 230 Vac at 50/60 Hz, 50 mA
  • Input Power Requirement: 24 Vdc at 250 mA

Materials of Construction

  • Inline Flowmeter: Stainless Steel Ferrule
  • Insertion Flowmeter: Teflon Ferrule

NACE & NIST

  • NIST

NPT Connection

  • 3-1/2” NPT Male

Operating Temperature

  • -18° to 55° C (0° to 130° F)

Output

  • Linear Signal Output: 0-10 Vdc
  • Linear Signal Output: 0-5 Vdc
  • Linear Signal Output: 4-20 mA

Power Requirement

  • Transmitter: 5 W or Less

Pressure Rating

  • Inline Flowmeter, Insertion Flowmeter (Stainless Steel Ferrule) - psig: 500 (kPa: 3,447, bar: 34.47) - Max.
  • Insertion Flowmeter (Teflon Ferrule) - psig: 25 (kPa: 172.4, bar: 1.724) - Max.
  • Insertion Flowmeter (with Locking Collar & Safety Cable) - psig: 250 (kPa: 1,724, bar: 17.24) - Max.

Relay Output

  • Relay Output Rating: 1 A at 30 Vdc (33 W) (2 Relays, 1 if Frequency Out Needed)

Repeatability

  • ± 0.2 % of Full Scale

Response Time

  • Sensor: 1 second

Sensor, Probe Length

  • Insertion Style Flowmeter (Probe): 6 to 18” (152.4 to 457.2 mm)

Size

  • Inline Style Flowmeter: 1/4” to 2” (6.35 to 51 mm)

Temperature Range

  • Standard Temperature & Pressure (STP): 21° C (70° F) & 29.92” Hg (Air = 0.075 lbs/ft³)

Turndown

  • 100:1 (Not less than 15 scfm/FT²)

Wetted Materials

  • 316 Stainless Steel
  • 316L Stainless Steel

show more