Price
Request a Quote
Stock
Call for Pricing & Availablility

  • Recording Points - 6 Continuous Recording
  • Power Supply - 100-240 Vac, 50/60 Hz
  • Chart Paper - Without Chart Paper Illumination
  • Alarm Output / External Control - Without
  • Transmission Function - Without

Specifications

Accuracy

  • Chart Speed Accuracy: ± 0.1 % (Expansion & Contraction of Paper is Not Included)
  • Clock Accuracy: ± 50 ppm or Less (Monthly Error, About 2 minutes)
  • Reference Junction Compensation (K, E, J, T, N, L, U, PN Thermocouple): ± 0.5° C (± 0.9° F)
  • Reference Junction Compensation (R, S, B, W Thermocouple): ± 1° C (± 1.8° F)
  • Thermocouple, Resistance Bulb, DC Voltage: ± (0.15 % + 1-Digit)
  • Thermocouple, RTD, DC Voltage: ± 0.25 % of Recording Span

Communication

  • Transmission Method: Half-Duplex Bit Serial, 500 Kbps Up to, Max.

Consumption

  • 100 Vac & 24 Vdc with All Options Approximately: 37 VA
  • 240 Vac with All Options Approximately: 56 VA

Electrical Contacts

  • Normally Open

Electrical Rating

  • 3 A at 240 Vac / 30 Vdc
  • Contact Capacity: 0.05 A at 12 Vdc, Normally Open

Enclosure, Body Material

  • Steel Plate

Environmental Protection

  • Front: IEC IP50
  • Terminal: IP20

Function

  • Alarm
  • Recording Switch on Camera

Humidity

  • Chart Paper Influence (Contraction): 35 % Relative Humidity, 0.5 %, Max.
  • Chart Paper Influence (Expansion): 85 % Relative Humidity, 0.4 %, Max.
  • Operating Environment: 20 to 80 % Relative Humidity, Non-Condensing
  • Transportation/Storage Condition: 5 to 90 % Relative Humidity, Non-Condensing

Hysteresis

  • 0.5 % of Recording Span

Indication

  • Status Display Icon

Input

  • DC Voltage Input (5 V, 50 V Range): -100 to 100 Vdc or Less
  • Thermocouple, Resistance Bulb & DC Voltage (50 mV, 500 mV Range): -10 Vdc or Less

Input Signal

  • -50 to 50 V
  • -500 to 500 mV

Insulation Resistance

  • 100 megaohms or more (Between Each Terminal & Earth, at 500 Vdc)

Materials of Construction

  • Front Door Frame: Polycarbonate with Glass Wool

Mounting

  • Inclined up to 30° Backwards from the Vertical: Panel

Mounting Position

  • Front & Left/Right Inclination: 0°
  • Rear Inclination: 30°

Mounting Position Effect

  • Change in Indication: ± (0.1 % + 1-Digit) - Max.
  • Changing in Recording: ± 0.2 % of Recording Span, Max.

Operating Temperature

  • 0° to 50° C (32° to 122° F)

Output Noise

  • Common Mode Noise Rejection: 120 dB at 50, 60 Hz ± 0.1 Hz
  • Series Mode Noise Rejection: 30 dB at 50, 60 Hz ± 0.1 Hz

Power Supply

  • 100-240 Vac (10 %, ± 15 %), 50/60 Hz
  • 24 Vdc, ± 10 %

Power Supply Effect

  • Change in Indication: ± (0.1 % + 1-Digit) - Max.
  • Change in Recording: ± 0.2 % of Recording Span, Max.

Resistance

  • Input (5 V & 50 V): ≥ 1 Megaohm
  • Input (Thermocouple & 50 mV): > 10 megaohms
  • Iput (500 mV): > 100 kiloohms
  • Signal Source Resistance (Resistance Bulb Input): less than 10 ohms Per Line
  • Signal Source Resistance (Thermocouple Input): 1 Kiloohm or Less Voltage

Resistance Effect

  • Change in Indication (Thermocouple & RTD): ± (0.1 % + 1-Digit)
  • Change in Recording (Thermocouple & RTD): ± 0.2 % of Span
  • Voltage Input: 0.1 % Change of Resistance

Resolution

  • DC Voltage: 10 µA to 10 mA
  • Thermocouple, Resistance Bulb: 0.1° C
  • Thermocouple, RTD, DC Voltage: 0.1 mm Min.

RTD Type

  • Pt100 as Per IEN 60751

Sensor, Probe Type

  • B Thermocouple as Per EN 60584
  • C Thermocouple
  • D Thermocouple
  • E Thermocouple
  • J Thermocouple
  • K Thermocouple
  • L Thermocouple as Per DIN 43710
  • N Thermocouple
  • PN Thermocouple
  • RTD
  • R Thermocouple
  • S Thermocouple
  • T Thermocouple
  • U Thermocouple as Per DIN 43710

Shock

  • 294 m/sec² (30 G) or Less

Storage Temperature

  • -10° to 60° C (14° to 140° F)

Supply Voltage

  • Withstand Voltage: between Alarm Terminals 750 Vac for 1 Minute
  • Withstand Voltage: Input Terminal - Input Terminal, Input Terminal - Ground, Power Terminal - Input Terminal 500 Vac for 1 Minute
  • Withstand Voltage: Power Supply Terminal - Ground 2,000 Vac for 1 Minute

Temperature Effect

  • Change in Indication: ± (0.3 % + 1-Digit)/10° C (18° F) - Max.
  • Change in Recording: ± 0.5 %/10° C (18° F) - Max.

Temperature Range

  • RTD: -200° to 600° C (-328° to 1,112° F)
  • Thermocouple: -200° to 1,760° C (-328° to 3,200° F)

Terminal Strip

  • External Terminals: Screw Terminal Strip (M4 Screws)

Update Time

  • Warm-Up Time: 30 minutes or more

Vibration

  • Operating Environment: 10-60 Hz, 0.2 m/sec² (0.02 G) or Less
  • Transportation/Storage Condition: 2.45 m/sec² (3 G) or Less

Vibration Effect

  • Change in Indication: ± (0.1 % + 1-Digit) - Max.
  • Change in Recording: ± 0.2 % of Recording Span, Max.

show more