Price
Request a Quote
Stock
Call for Pricing & Availablility

  • Recording Points - 1 Continuous Recording
  • Input Signal for Channel 1 - B Thermocouple
  • Input Signal for Channel 2 - No Input Signal for Channel 2
  • Power Supply - 100/120 Vac, 50/60 Hz
  • Scale Range 1 - One Channel
  • Scale Range 2 - One Channel
  • Alarm Output - No Alarm Output

Specifications

Accuracy

  • Chart Speed Accuracy: ± 0.1 %
  • Recording Accuracy (Indicating): ± 0.2 %
  • Reference Junction Compensation Accuracy (K, E, J, T, N, L, U, PN): ± 0.5° C (0.9° F)
  • Reference Junction Compensation Accuracy (R, S, B, W): ± 1° C (1.8° F)

Approvals & Certifications

  • CE
  • EMC - EN 50081-1 (1992), EN 50082-1 (1992)
  • IEC 1010-1 (1990)

Approvals & Certifications

  • ISO 9001

Consumption

  • Power (with Options): Approximately 15 VA at 100-120 Vac, 200-240 Vac
  • Power (without Options): Approximately 13 VA at 100-120 Vac, 200-240 Vac

Display

  • LED (7-Segment Alphanumeric, 10 mm High, 5 mm Wide), 6-Digits, Green

Electrical Connectors

  • Screw Terminals (M4 Thread)

Electrical Rating

  • 0.05 A at 12 Vdc
  • 3 A at 240 Vac (Resistive Load)
  • 3 A at 30 Vdc - Resistive Load

Enclosure, Body Material

  • Plastic Mold

Environmental Protection

  • IP50

Frequency

  • Supply Frequency: 50/60 Hz

Humidity

  • 20 to 80 % Relative Humidity, Non-Condensing
  • Chart Paper Influence: 65 % Relative Humidity
  • Chart Paper Influence: Contraction at 35 % Relative Humidity, 0.5 %, Max.
  • Chart Paper Influence: Expansion at 85 % Relative Humidity, 0.4 %, Max.

Hysteresis

  • Hysteresis Amplitude: 0.2 % of Recording Span

Input

  • 10-50 mA DC
  • 1-5 Vdc
  • 4-20 mA DC, Converted Into Voltage with 10 ohms or 250 ohms Shunt Resistor
  • -5 to 5 Vdc
  • -50 to 50 mVdc
  • -50 to 50 Vdc
  • -500 to 500 mVdc
  • DC Voltage Input (5 V, 50 V Range): ± 100 Vdc or Less - Max.
  • Thermocouple, RTD & DC Voltage (50 mV, 500 mV Range): ± 10 Vdc or Less - Max.
  • Thermocouple: 10 µV Per 100 ohms

Isolation

  • 100 megaohms (Between Each Terminal & Ground, at 500 Vdc)

Mounting

  • Panel Flush Mounting

Mounting Position

  • Front & Left/Right Inclination: 0°
  • Inclination Angle: 90° to 60° from Horizontal
  • Rear Inclination: 30°

Operating Temperature

  • 0° to 50° C (32° to 122° F)

Operating Voltages

  • 180-264 Vac
  • 85-132 Vac

Power Supply

  • 100-120 Vac
  • 200-240 Vac

Resistance

  • Input (5 V & 50 V Range): ≥ 1 Megaohm
  • Input (500 mV Range): ≥ 100 kiloohms
  • Input (Thermocouple, 50 mV Range): ≥ 10 megaohms
  • RTD: 10 ohms / Wire [Change in Indication: ± (0.1 % of Reference Range + 1-Digit) - Max.
  • Signal Source Resistance: 1 Kiloohm

Resolution

  • Recording Resolution: 0.1 mm

RTD Type

  • Pt100 ohm

Sensor, Probe Type

  • B Thermocouple
  • E Thermocouple
  • J Thermocouple
  • K Thermocouple
  • L Thermocouple
  • N Thermocouple
  • PN Thermocouple
  • RTD
  • R Thermocouple
  • S Thermocouple
  • T Thermocouple
  • U Thermocouple
  • W Thermocouple

Time Constant

  • Input Filter: 0 to 255 seconds

Vibration

  • 0.2 m/sec² (0.02 G) or Less, 10-60 Hz

Voltage

  • Withstand Voltage (Between Two Input Terminals, Input Terminal to Ground): 500 Vac, 1 Minute
  • Withstand Voltage (Power Terminal to Ground): 2,000 Vac, 1 Minute

show more