Price
Request a Quote
Stock
Call for Pricing & Availablility

  • Number of Input Points - 3-Points
  • Alarm (Relay) Output / DI Input - Without Alarm (Relay) Output / DI Input
  • Communication - Without Any Communication

Specifications

Accuracy

  • Clock: ± 50 ppm or Less
  • Digital Indication (K Thermocouple): ± (0.3 % + 1-Digit)
  • Digital Indication (Ni100, Cu50 Resistance Bulb): ± (0.5 % + 1-Digit)
  • Digital Indication (R Thermocouple, JPt100, Pt100, Pt50 Resistance Bulb, DC Voltage): ± (0.15 % + 1-Digit)

Ambient Temperature Range

  • With Ethernet Function: 0° to 40° C (32° to 104° F)
  • Without Ethernet Function: 0° to 50° C (32° to 122° F)

Approvals & Certifications

  • EMC EN 61326
  • IEC 61010-1

Bezel Material

  • PC-ABS

Burn-Out

  • Approximately 0.2 µA

Communication

  • Ethernet
  • FTP
  • HTTP
  • Modbus TCP/IP
  • SMTP (E-mail Client)

Consumption

  • Power: 32 VA at 100 Vac
  • Power: 42 VA at 240 Vac

Electrical Connectors

  • M3 Screw Terminal

Enclosure Finish

  • Black

Enclosure, Body Material

  • PC-ABS

Frequency

  • Effect of Power Supply Fluctuation Conditions: 47 to 63 Hz (100 Vac) [Reading Change: ± (0.2 % + 1-Digit) or Lower]
  • Power Supply, Normal Operating Condition (± 2 %): 50/60 Hz (Both Employable)

Function

  • Burn-Out
  • Input Filter
  • Scaling
  • Square Rooter
  • Subtraction

Humidity

  • Ambient: 20 to 80 % Relative Humidity
  • Transportation/Storage Conditions: 5 to 90 % Relative Humidity, Non-Condensing

Hysteresis

  • Alarm Function: 0 to 100 %

Indication

  • 5.7” STN Color LCD (320 x 240 Dots) with Backlight

Input

  • 0-5 Vdc
  • 0-500 mVdc
  • Resistance Bulb Measured Current: 1 mA
  • Thermocouple, Resistance Bulb, DC Voltage: ± 10 Vdc (Continuous) - Max.

Insulation Resistance

  • 100 megaohms or more (When Measured between Each Terminal & Ground by Using A 500 Vdc Megger)

Measuring Range

  • Resistance Bulb: -200° to 600° C (-328° to 1,112° F)
  • Thermocouple: -200° to 1,760° C (-328° to 3,200° F)

Mounting

  • Panel-Mounted (Vertical Panel)

Mounting Position

  • Backward Tilt within 30° Slant [Reading Change: ± (0.2 % + 1-Digit) or Lower]
  • Mounting Posture (Forward Tilt & Horizontal): 0°

Operating Voltages

  • 90-264 Vac

Output

  • Alarm Relay Output: 3 A at 150 Vac/240 Vac (Resistive Load), 3 A at 30 Vdc

Power Supply

  • Rated: 100-240 Vac

Pulse Range

  • DI Input Pulse Width (ON/OFF): 200 milliseconds or Longer

Resistance

  • Input (Thermocouple, DC Voltage): 1 Megaohm (At Power ON)
  • Input (Thermocouple, DC Voltage): 100 kiloohms (At Power OFF)
  • Signal Source Resistance (Resistance Bulb Input): 10 ohms/Wire or Less
  • Signal Source Resistance (Thermocouple Input): 1 Kiloohm or Less

Resistance Effect

  • Thermocouple Input: 30 µV ± 1-Digit / 100 ohms

Resolution

  • Digital Indication (0-5 Vdc & 1-5 Vdc): 1 mV
  • Digital Indication (50 mVdc Voltage): 10 µV
  • Digital Indication (500 mVdc Voltage): 100 µV
  • Digital Indication: 0.1° C (0.18° F) for Thermocouple & Resistance Bulb

RTD Type

  • Cu50
  • JPt100
  • Ni100
  • Pt100
  • Pt50

Sensor, Probe Type

  • B Thermocouple
  • E Thermocouple
  • J Thermocouple
  • K Thermocouple
  • L Thermocouple
  • N Thermocouple
  • PN Thermocouple
  • R Thermocouple
  • S Thermocouple
  • T Thermocouple
  • U Thermocouple
  • W Thermocouple

Shock

  • Transportation/Storage Conditions: 294 m/sec² or Lower (Packed State)

Storage Temperature

  • -10° to 60° C (14° to 140° F)

Switch Type

  • SPST

System Requirements

  • Windows® 2000/XP

Temperature Effect

  • Ambient (Reading Change): ± (0.3 % + 1-Digit)/10° C or Lower

Temperature Range

  • Thermocouple B: 400° to 600° C (752° to 1,112° F)
  • Thermocouples K, E, J, T, L & U: -200° to -100° C (-328° to -148° F)
  • Thermocouples R & S: 0° to 300° C (32° to 572° F)
  • Transportation: -10° to 60° C (14° to 140° F)

Time Constant

  • Input Filter Function: 0 to 900 seconds

Vibration

  • Normal Operating Condition: 10-60 Hz, 0.2 m/sec² or Less [Reading Change: ± (0.2 % + 1-Digit) or Lower]
  • Transportation/Storage Conditions: 10-60 Hz, 2.45 m/sec² or Lower

Voltage

  • Withstand Voltage [Alarm Terminal - Alarm Terminal]: 750 Vac, 1 Minute
  • Withstand Voltage [Input Terminal - Ground, Communication Terminal - Ground]: 500 Vac, 1 Minute
  • Withstand Voltage [Power Terminal - Ground, Alarm Terminal - Ground]: 2,000 Vac, 1 Minute

show more