  • Number of Input Points - 9-Points
  • DI Input - Without DI Input
  • Instruction Manual - English
  • Alarm Output - Without Alarm Output
  • Ethernet - Without Ethernet

Specifications

Accuracy

  • Clock: ± 50 ppm
  • Digital Indication (K Thermocouple): ± (0.3 % + 1-Digit)
  • Digital Indication (Ni100, Cu50 Resistance Bulb): ± (0.5 % + 1-Digit)
  • Digital Indication (R Thermocouple, JPt100, Pt100, Pt50 Resistance Bulb, DC Voltage): ± (0.15 % + 1-Digit)

Ambient Temperature Range

  • With Ethernet Function: 0° to 40° C (32° to 104° F)
  • Without Ethernet Function: 0° to 50° C (32° to 122° F)

Approvals & Certifications

  • EMC EN 61326
  • IEC 61010-1

Burn-Out

  • Approximately 0.2 µA

Communication

  • Ethernet
  • FTP
  • HTTP
  • Modbus TCP/IP
  • SMTP (E-mail Client)

Consumption

  • Power: 65 VA at 100 Vac
  • Power: 80 VA at 240 Vac

Electrical Connectors

  • External Terminal Board (Input Terminal): M3 Screw Terminal
  • External Terminal Board (Power Terminal): M4 Screw Terminal

Electrical Rating

  • Alarm Relay: 3 A at 240 Vac (Resistive Load)
  • Alarm Relay: 3 A at 30 Vdc - Resistive Load
  • Alarm: 0.1 A at 30 Vdc - Resistive Load

Enclosure, Body Material

  • Stainless Steel

Frequency

  • Effect of Power Supply Fluctuation Conditions: 47 to 63 Hz (100 Vac) [Reading Change: ± (0.2 % + 1-Digit) or Lower]
  • Power Supply: 50/60 Hz ± 2 % (Both Employable & Sharing)

Function

  • Burn-Out
  • Computation
  • F Value Calculation
  • Input Filter
  • Scaling
  • Square Rooter
  • Subtraction
  • Totalization

Humidity

  • Ambient: 20 to 80 % Relative Humidity
  • Transportation/Storage Conditions: 5 to 90 % Relative Humidity

Hysteresis

  • Alarm Function: 0 to 100 %

Indication

  • 12” TFT Color LCD (800 x 600 Dots) with Backlight, No Contrast Adjustment

Input

  • 0-5 Vdc
  • DC Voltage: 0-500 mV
  • Thermocouple, Resistance Bulb, DC Voltage: ± 10 Vdc (Continuous) - Max.

Input Impedance

  • Thermocouple, DC Voltage: 1 Megaohm

Insulation Resistance

  • 100 megaohms (When Measured between Each Terminal & Ground by Using A 500 Vdc Megger)

Materials of Construction

  • Bezel: PC-ABS

Measuring Error

  • K, E, J, T, N, L, U, PN Thermocouple: ± 0.5° C (0.9° F)
  • R, S, B, W Thermocouple: ± 1° C (1.8° F)

Measuring Range

  • Resistance Bulb: -200° to 600° C (-328° to 1,112° F)
  • Thermocouple: -200° to 1,760° C (-328° to 3,200° F)

Mounting

  • Panel-Mounted (Vertical Panel)

Mounting Position

  • Backward 30° Slant [Reading Change: ± (0.2 % + 1-Digit) or Lower]

Operating Voltages

  • 90-264 Vac

Power Supply

  • 90-264 Vac at 50/60 Hz
  • Rated: 100-240 Vac

Pulse Range

  • Input Pulse Width (ON/OFF): 400 milliseconds

Resistance

  • Signal Source Resistance (Resistance Bulb Input): 10 ohms/Wire or Less [Reading Change: ± (0.2 % + 1-Digit) or Lower]
  • Signal Source Resistance (Thermocouple Input): 1 Kiloohm or Less

Resistance Effect

  • Effect of Input Signal Resistance (Thermocouple Input): 50 μV ± 1-Digit/100 ohms

Resolution

  • Digital Indication: 0.1° C (0.18° F) for Thermocouple & Resistance Bulb
  • Digital Indication: 1 mV for 5 Vdc
  • Digital Indication: 10 V for 50 mVdc
  • Digital Indication: 100 V for 500 mVdc

RTD Type

  • Cu50
  • JPt100
  • Ni100
  • Pt100
  • Pt50

Sensor, Probe Type

  • B Thermocouple
  • E Thermocouple
  • J Thermocouple
  • K Thermocouple
  • L Thermocouple
  • N Thermocouple
  • PN Thermocouple
  • R Thermocouple
  • S Thermocouple
  • T Thermocouple
  • U Thermocouple
  • W Thermocouple

Shock

  • Transportation/Storage Conditions: 294 m/sec² or Lower (Packed State)

Storage Temperature

  • -10° to 60° C (14° to 140° F)

System Requirements

  • Windows® 2000/XP (Windows® Vista is Not Supported)

Temperature Effect

  • Ambient (Reading Change): ± (0.3 % + 1-Digit)/10° C or Lower

Temperature Range

  • Transportation: -10° to 60° C (14° to 140° F)

Time Constant

  • Input Filter Function: 0 to 900 seconds

Vibration

  • 10-60 Hz with the Acceleration of 0.2 m/sec² or Less [Reading Change: ± (0.2 % + 1-Digit) or Lower]
  • Transportation/Storage Conditions: 10-60 Hz, 2.45 m/sec² or Lower

Voltage

  • Withstand Voltage [Alarm Terminal (Contact Output) - Alarm Terminal (Contact Output)]: 750 Vac, 1 Minute
  • Withstand Voltage [Input Terminal - Input Terminal, Input Terminal - Ground, Communication Terminal - Ground, Alarm Terminal (Open Collector) - Ground, Power Terminal - Input Terminal]: 500 Vac, 1 Minute
  • Withstand Voltage [Power Terminal - Ground, Alarm Terminal (Contact Output) - Ground]: 2,000 Vac, 1 Minute

show more